- JENOPTIK
- 耶拿LDM3000
- ASTECH激光測距傳感器
- DIMETIX激光測距傳感器
- 美國LTI 激光傳感器
- RIFTEK激光傳感器
- 中長距離激光傳感器
- TOF激光測距傳感器
- 短距離激光傳感器(三角測量)
- LOKE激光測距傳感器
- 激光測距模塊/進(jìn)口測距模塊
- FAE意大利激光傳感器
- ACR激光測距傳感器
- 國產(chǎn)激光測距傳感器
- 芬蘭noptel激光測距傳感器
- LASE激光傳感器
- SICK遠(yuǎn)程距離傳感器
- 美國雷達(dá)速度傳感器
- 高精度激光測距傳感器
- 遠(yuǎn)距離激光測距傳感器
- 高溫型激光測距傳感器
- 勞易測激光測距傳感器
- 激光測距儀
- ACUITY激光測距傳感器
- 交通調(diào)查儀
帶DP接口PROFIBUS激光測距傳感器
- 產(chǎn)品名稱:帶DP接口PROFIBUS激光測距傳感器
- 產(chǎn)品型號:LDM42P
- 產(chǎn)品廠商:耶拿
- 產(chǎn)品文檔:
帶DP接口PROFIBUS激光測距傳感器
的詳細(xì)介紹帶DP接口PROFIBUS激光測距傳感器 LDM42P
	
帶DP接口PROFIBUS激光測距傳感器 LDM42P
帶DP接口PROFIBUS激光測距傳感器 LDM42P
	
	The LDM41P is an optoelectronic distance measuring device for industrial applications with integrated Profibus DP interface.
It works contact-free on the principle of comparative phase measurement (amplitude modulation) and facilitates precisely accurate measurement of distances.
	
	 
		Both, the LDM41P and the LDM42P distinguish themselves through high precision as well as high independence from the surface of the measuring object. The red, well visible laser beam allows for easy alignment. The LDM42P has been further developed for fast distance measurements on white surfaces. 
		 
		
		 
			 
								0.2 m ... 30 m on almost all natural surfaces, over 100 m achievable depending on the degree of reflection of surfaces 
							 
								0.1 mm, freely scalable
							 
								0.5 mm
							 
								0.24 s ... 6 s adjustable or automatically in mode DT 
								10 V ... 30 V direct currents
							 
								RS232 or optional RS422, max. Baud rate 38400, ASCII, setting of measuring functions, scaling, measuring time via commands, display of measured values, internal temperature of the device and error code
							 
								Programmable switching threshold and hysteresis, "high side" switch, maximum load 0.5 A
							 
								Aluminum anodized
							 
								4 drill holes for M6 screws, 100 mm x 85 mm
							
Through the integrated Profibus DP interface it is possible to read in data of several devices into a control easily. 
	
Applications
	
		
	
			
				
					
						 
					
							Measuring range1
						 
						
							 
					
						 
					
							Measuring uncertainty2
						 
						
							±2 mm under defined measuring conditions3 
					
±3 mm (+15°C ... +30°C)
±5 mm (-10 °C ... +50 °C)
						
						 
					
							Resolution
						 
						
							 
					
						 
					
							Reproducibility4
						 
						
							 
					
						 
					
							Measuring time
						 
						
							 
					
0.1 s in mode DW on white surface
20 ms in mode DX on white surface (only LDM42P) 
							
						 
					
							Laser class
						 
						
							Laser class 2 acc. to DIN EN 60825-1:2001-11
						 
					
						 
					
							Laser divergence5
						 
						
							0.6 mrad
						 
					
						 
					
							Operating temperature
						 
						
							-10 °C ... +50 °C
						 
					
						 
					
							Storage temperature
						 
						
							-40 °C ... +70 °C
						 
					
						 
					
							Supply voltage
						 
						
							 
					
						 
					
							Power consumption
						 
						
							Ca. 3.5 W
						 
					
						 
					
							Serial interface6
						 
						
							 
					
						 
					
							Fieldbus6
						 
						
							Profibus DP-V0  
					
12 MBit, Autodetect
						
						 
					
							Switching output
						 
						
							 
					
						 
					
							Housing material
						 
						
							 
					
						 
					
							Size (LxBxH)
						 
						
							187 mm x 96 mm x 50 mm
						 
					
						 
					
							Weight
						 
						
							850 g
						 
					
						 
					
							Protection class
						 
						
							IP 65
						 
					
						 
					
							Shock resistance
						 
						
							10 g / 6 ms (DIN ISO 9022-3-31-01-1)
						 
					
						 
					
							MTBF
						 
						
							30,000 hours at 25 °C
						 
					
						 
				
			
							Mounting
						 
						
							 
					
			
				
					
			
						 
					
						 
					
						 
					
							Bemerkungen zu den technischen Daten: 
						 
					
						 
				
			
						 
					
				
					
		
						 
					
							1
						 
						
							Dependent on target reflectance, influence of extraneous light and atmospheric conditions
						 
					
						 
					
							2
						 
						
							Statistical spread of 95 %
						 
					
						 
					
							3
						 
						
							Measurement on planar, vertical white surface at standstill or in continuous movement, + 15 °C to +30 °C
						 
					
						 
					
							4
						 
						
							Dependent on target reflectance, influence of extraneous light and atmospheric conditions
						 
					
						 
					
							5
						 
						
							At a distance of 10 m the beam diameter is 6 mm, at 100 m it is 6 cm
						 
					
						 
				
			
							6
						 
						
							Please specify option RS422 when placing the order
						 
					
 
    